Our most popular general purpose power supply. The output voltage is selected by a rotary switch on the front of the unit, output is in 1V steps up to a maximum of 13V. It provides 0 - 13V ac or unsmoothed dc in 1V steps at a maximum current of 8.5A. The ac and dc outputs may be used simultaneously, provided the combined output does not exceed 8.5A. Internal heavy duty relays allow the voltage to be switched without switch contact problem, ensuring long switch lifetime. 

The internal, quiet-running fan will hardly be noticed but it reduces the already low thermal stress in the unit still further, ensuring long life of the instrument. Triple protection is provided by a resettable electronic overload trip, thermal transformer trip and slow-blow fuse on the primary. 

Overloads are indicated by the LED changing from green to red.

The mains cord is kept tidy, by means of the cable retainer on the back of the unit which allows the cable to be stowed away neatly with the use of winding hooks and a clip to secure the cable.

The unit is recommended for general purpose laboratory work by teachers, technicians and students.

  • Output voltage selected by rotary switch in 1V steps up to 13V
  • Long switch lifetime - switch voltage safely at full load without switch contact arcing
  • Continuously rated output of 8.5A, a.c. or d.c.
  • Sockets accept standard 4mm plugs and shrouded plugs
  • Snap up handle - safe to carry with one hand
  • Internal fan for cool-running under load
  • Fully protected secondary, by high speed, resettable electronic trip
  • Slow-blow fuse protection for primary
  • Additional thermal trip protection for transformer
  • Compliant to EN61010-2010 with certificates available on request

Dimensions:

  • Width: 175mm.
  • Depth: 190mm (including cable clips 206mm).
  • Height: 298mm.
  • Mass: 4.8kg.
  • Robust
  • Rotary Voltage Selection
  • Maximum Current: 8.5A
  • Applications throughout Key Stage 3, GCSE and A-Level
  • The overload light will change from green to red if the attached circuit is overloaded.

Further Information

Age Recommended from
11 Years
Brand
Unilab
Fuse
1A Time Delay
Humidity (% RH)
10 - 90
Maximum Voltage
13V
Offers
Buy More Save More
Output
ac and dc
1 - 13V
unsmoothed
Output Control
Stepped
Power Supply Type
Spacesaver Bench
Product Type
Power Supply Units
Ratings
230V ac 50Hz 155VA
Temperature Range (°C)
10 - 40

Documents

-
+

Our most popular general purpose power supply. The output voltage is selected by a rotary switch on the front of the unit, output is in 1V steps up to a maximum of 13V. It provides 0 - 13V ac or unsmoothed dc in 1V steps at a maximum current of 8.5A. The ac and dc outputs may be used simultaneously, provided the combined output does not exceed 8.5A. Internal heavy duty relays allow the voltage to be switched without switch contact problem, ensuring long switch lifetime. 

The internal, quiet-running fan will hardly be noticed but it reduces the already low thermal stress in the unit still further, ensuring long life of the instrument. Triple protection is provided by a resettable electronic overload trip, thermal transformer trip and slow-blow fuse on the primary. 

Overloads are indicated by the LED changing from green to red.

The mains cord is kept tidy, by means of the cable retainer on the back of the unit which allows the cable to be stowed away neatly with the use of winding hooks and a clip to secure the cable.

The unit is recommended for general purpose laboratory work by teachers, technicians and students.

  • Output voltage selected by rotary switch in 1V steps up to 13V
  • Long switch lifetime - switch voltage safely at full load without switch contact arcing
  • Continuously rated output of 8.5A, a.c. or d.c.
  • Sockets accept standard 4mm plugs and shrouded plugs
  • Snap up handle - safe to carry with one hand
  • Internal fan for cool-running under load
  • Fully protected secondary, by high speed, resettable electronic trip
  • Slow-blow fuse protection for primary
  • Additional thermal trip protection for transformer
  • Compliant to EN61010-2010 with certificates available on request

Dimensions:

  • Width: 175mm.
  • Depth: 190mm (including cable clips 206mm).
  • Height: 298mm.
  • Mass: 4.8kg.
  • Robust
  • Rotary Voltage Selection
  • Maximum Current: 8.5A
  • Applications throughout Key Stage 3, GCSE and A-Level
  • The overload light will change from green to red if the attached circuit is overloaded.

Further Information

Age Recommended from
11 Years
Brand
Unilab
Fuse
1A Time Delay
Humidity (% RH)
10 - 90
Maximum Voltage
13V
Offers
Buy More Save More
Output
ac and dc
1 - 13V
unsmoothed
Output Control
Stepped
Power Supply Type
Spacesaver Bench
Product Type
Power Supply Units
Ratings
230V ac 50Hz 155VA
Temperature Range (°C)
10 - 40

Documents

You May Also Like

Shopping from Overseas?

We have detected that your IP address is not UK based.

We have a specific international website which deals with all non-UK transactions and deliveries. Please select which website you would like to continue with.

For International Delivery

Findel Education family logos Switch to Findel International

For Delivery in the UK

Brand logo